Absolute Maximum, Thermal & Pin Cautions
Check your design against the limits the datasheet states.
Extracts absolute maximum ratings, thermal limits and resistance, and pin cautions from a datasheet, each with a source page where one was recorded. Stress limits stay apart from operating conditions, and a design value can be checked against the pin-cautions rules through the API.
TI LM1117 (SOT-223)
Real run · SNOS412Q page 4
Recommended junction range: 0 to 125 °C for the LM1117 and −40 to 125 °C for the LM1117I.
Computed by code as (TJ limit − TA) / RθJA from the extracted values, with the 150 °C absolute-maximum TJ as the limit. Verify board and test conditions before design use.
- Stress-Only
- Limits tagged as damage boundaries
- TJ = TA + PD · θJA
- Computed from extracted values
- Rule Check API
- One design value against the rulebook
- Source Pages
- Attached where recorded
Try The Arithmetic
Check A Value Against A Stated Limit
These four calculators run in your browser on numbers printed in real datasheets (the TI LM1117 and the ATmega328P). They show the arithmetic the limits imply. They are illustrations. The product's own checks run on the data extracted from your datasheet.
Stress Limit vs Operating Range
Absolute Maximum Is Not A Design Limit
The LM1117 datasheet gives 20 V as the absolute maximum on VIN and 15 V as the recommended maximum. A rating is a damage boundary, so a value between the two is outside the recommended range even though it is below the stress limit.
12.0 V against a recommended maximum of 15 V and an absolute maximum of 20 V. This compares one number. Other limits in the datasheet still apply.
Who It Is For
Useful To Every Stakeholder
Limits and cautions are cheapest to check during schematic capture and most expensive to diagnose on a prototype bench.
For Hardware Engineers
Check input voltage, current budgets and junction temperature against the limits the datasheet states, each with its source page where one was recorded.
For Firmware Engineers
Find the reset, boot and pull-up cautions a datasheet keeps in footnotes and programming sections, each with a severity, a lifecycle phase and a source snippet.
For Engineering Directors
Get JSON records with warnings and review flags in place of a spreadsheet checklist. Each module says whether a person should review it before the data is used.
Real Output Files
Machine-Readable Limits And Cautions
Each module returns a JSON contract with source pages, review flags and an audit record. These files are abridged from real runs: the LM1117 for thermal, and the ATmega328P for the rest.
// Abridged from a real run on the ATmega328P datasheet. Omissions are marked with …
// 3 of 27 ratings shown.
{
"contract_version": "absolute_max_canonical_v2",
"module_id": "absolute_max",
"contract_kind": "canonical",
"schema_version": "absolute_max_v2",
"ratings": [
{
"category": "supply_voltage",
"severity": "critical",
"parameter": "Maximum operating voltage",
"min_value": null,
"max_value": 6,
"unit": "V",
"design_use": "stress_only_not_for_operation",
"evidence": {
"source_page": 258,
"source_table_title": "28.1 Absolute Maximum Ratings",
"source_text_snippet": "Maximum operating voltage 6.0 V"
},
"confidence_score": null,
"review_required": false
},
{
"category": "io_current",
"severity": "high",
"parameter": "DC current per I/O pin",
"min_value": null,
"max_value": 40,
"unit": "mA",
"design_use": "stress_only_not_for_operation",
"evidence": {
"source_page": 258,
"source_table_title": "28.1 Absolute Maximum Ratings",
"source_text_snippet": "DC current per I/O pin 40.0 mA"
},
"confidence_score": null,
"review_required": false
},
{
"category": "aggregate_current",
"severity": "critical",
"parameter": "DC current VCC and GND pins",
"min_value": null,
"max_value": 200,
"unit": "mA",
"design_use": "stress_only_not_for_operation",
"evidence": {
"source_page": 258,
"source_table_title": "28.1 Absolute Maximum Ratings",
"source_text_snippet": "DC current VCC and GND pins 200.0 mA"
},
"confidence_score": null,
"review_required": false
}
…
],
"recommended_operating_boundaries": [],
"esd_ratings": {},
"audit_summary": {
"rating_count": 27,
"source_backed_count": 13,
"stress_only_count": 13,
"review_required_count": 14,
"unknown_category_count": 14
}
}Engineering Truth Standard
Built For Review, Not Blind Trust
We say where extraction saves you time and where a person still has to check. A model reads the datasheet. Code does the arithmetic and writes the audit.
What Compliance Guard Does
- Reads absolute maximum ratings from the datasheet's tables and keeps them apart from recommended operating conditions.
- Reads thermal resistance and temperature limits, then computes maximum power from the extracted values.
- Reads pin cautions with a severity and lifecycle phase, and checks one design value against them through the API.
- Attaches a source page and snippet wherever the extraction recorded them.
What It Does Not Claim
- Static checks do not replace bench bring-up or lab qualification.
- It does not guess errata notes or silicon revisions the datasheet does not list.
- It flags rows it could not ground or attribute for review, and reports how many rules it could not check. In the rules/check sample above, 41 of 56 were not checkable.
- Extracted values can contain errors, so confirm each limit on its source page before you design to it.
Free To Try
Read the limits your next IC actually states
Upload a component datasheet and extract its thermal data and pin cautions on the free passes: a new account gets five, and each runs up to two modules. Absolute maximum ratings run on module credits.