01 · Document conflict
One register, two names: BME280 address 0xFE
Bosch Sensortec BME280 humidity, pressure and temperature sensor
Citation: BME280 data sheet BST-BME280-DS001-24, revision 1.24 (its page footers still read DS001-23): Table 18 (page 27) vs. Table 31 (page 31)
- What the datasheet says
- Table 18, the memory map on page 27, names address 0xFE "hum_lsb". Table 31 in section 5.4.9 on page 31 lists 0xFE as "temp_lsb[7:0]" and describes it as "Contains the LSB part uh[7:0] of the raw humidity measurement output data."
- Why it can hurt
- The name "temp_lsb" already belongs to address 0xFB in Table 18. A header or driver built from Table 31 can give the humidity low byte the temperature register's name.
- What DatasheetVend does
- Register-map rows carry the page where each register was recorded. A code check flags two different names at one address for review, but it can only compare names that reach the rows. In a stored run on this PDF, 0xFE came out once, as hum_lsb from page 27, so the page 31 table was not flagged. For any register you rely on, compare the pages.
Rule: Check a register's name in every table that prints it.
BME280 · Register map · Document conflict