Skip to main content

Unified Component Model

One datasheet in. One digital twin out.

A digital twin is one file, master.ucm.json, holding everything DatasheetVend extracted from a datasheet: pins, rails, interfaces, registers, limits, timing and package. Each fact keeps its provenance, with the page it came from where one was recorded, and the result of its checks, so an engineer, a script or an AI agent can work from it without re-reading the whole PDF.

Open the UCM workspace Works on datasheets you have already run through DatasheetVend.

Example twin: the ATmega328P, built on 12 September 2026 from its Atmel-7810 automotive datasheet

Facts
339
Registers
87
Modules combined
10
Passed every check
266

Inside a twin

What’s inside a twin

A datasheet describes a part at several levels, so the twin files each fact where it belongs. Only some facts belong to one pin; the rest describe a supply rail, an interface, a register or the chip as a whole.

  • Pins

    Each pin's name, alternate functions, cautions and pad position.

    PC4 (pin 27): also ADC4, SDA, PCINT12

  • Rails

    Supply ranges and logic thresholds for everything on that supply.

    VCC operating supply range: 2.7 to 5.5 V (page 258)

  • Interfaces

    Requirements for I2C, SPI, clocks, the ADC and other peripherals.

    I2C input low voltage: 0.3 × VCC (page 264)

  • Registers

    The register map: names, addresses, access and reset values.

    WDTCSR, Watchdog Timer Control Register: 0x60, read/write, reset 0x00 (page 47)

  • Whole part

    Temperature ranges, part-level limits, package geometry and the ordering code.

    Operating temperature range: −40 to 125 °C (page 2)

ModuleIts facts land onIn twins today
PinoutPins, the spine every other module attaches toYes
Pin CautionsPinsYes
Logic LevelsRails and interfacesYes
Absolute MaxThe whole part and supply railsYes
ThermalThe whole partYes
TimingInterfacesYes
Peripheral MatrixInterfacesYes
Register MapRegistersYes
Part DecoderThe whole part and its part numberYes
CAD CoordinatesPins (pad positions) and the whole part (package)Yes
Power & BatterySupply rails and the whole partYes
Analog IntelligenceInterfaces (ADC, DAC, comparators)Not yet
Passive BOMPins, rails and the whole partNot yet

How to build one

Build one in three steps

  1. Step 1

    Run the modules you need

    Each module is one extraction on your datasheet, priced per module in credits.

  2. Step 2

    Open the workspace and pick the datasheet

    Everything you ran on it is already combined into one twin, even across separate runs.

  3. Step 3

    Shape it in the combine tray

    Remove a module you don't trust, or extract one that's missing. The price shows before you click.

Trust

Know what to trust

Each fact carries the result of its checks. When values disagree, the twin keeps all of them and flags the disagreement; it does not pick one or average them. The counts are from the example twin.

  • 266

    Passed every check

    Nothing flagged it for review, no other value disagrees with it, and it sits in a plausible range.

  • 51

    Needs review

    Kept in the twin, but check it against the datasheet before relying on it.

  • 6

    Values disagree

    The twin holds more than one value for the same parameter. All of them are kept and none was chosen.

  • 16

    Failed a sanity check

    The value is outside a plausible range for what it claims to be. It is kept for audit only.

In practice

Use it

  • With your AI agent

    Download master.ucm.json and attach it to the assistant or agent you use. The workspace gives you a starter prompt, written for the part, that tells the agent to cite pages and treat unchecked facts as unverified.

  • In a spreadsheet

    master.ucm.csv lists each fact against every pin it reaches, or on its own when it reaches none, with its check result, a safe_for_agent column and the page.

  • Through MCP

    An agent connected to DatasheetVend's MCP server with your API key reads a twin directly with datasheetvend_get_component_twin: its summary, one pin, a section or a search, each fact with its check and, where one was recorded, its page. Reading is free. For a datasheet you have not extracted, datasheetvend_build_component_twin runs Fast Extraction and returns its twin in one call, billed per module; that twin is not saved.

  • From your own tools

    GET /api/v1/jobs/{id}/ucm returns the twin stored with an extraction job, using your API key.

Coverage

What UCM covers today

11 extraction modules feed a twin today. Analog Intelligence and Passive BOM are held back until their facts pass a page-by-page accuracy check.

Cookies. Strictly necessary cookies keep you signed in and remember this choice. Optional analytics (Google, Microsoft, PostHog) show us how the site is used. Cookie details