Verification
How an extraction is checked.
An extraction is only worth what you can check. A run keeps the page each value came from where the source has one, runs its own checks and ends with a verdict on what the result is safe for. Here are those checks, what they found on a real run, and what they missed.
What every output carries
Four things, every time.
The value
Named and typed against a published schema. The schemas are public at /api/v1/schemas.
The page it came from
Where the source has one, so the value can be checked against the datasheet.
The warnings
Everything the run flagged, left in, instead of smoothed away.
A review decision
What the output is safe for, what a person still has to look at, and a plain statement that none of it is production-approved.
The checks
What a run checks before it hands anything over.
01
The package comes first.
A pin table is only right for one package. A resolver reads it from the part number: STM32H743ZIT6 is an LQFP144 with 144 pins. When the part number does not settle it, the resolver returns nothing and a person chooses. See the STM32H743 notes.
02
A wrong count is thrown out.
Once the package is known, a pin table with a different count is rejected, not merged. The run logs it, for example:
Resolved target package expects 144 package pins, but candidate returned 100; rejecting wrong package candidate.
03
Every pin is counted.
Where the package’s pin count is known, the pinout verifier compares it with the pins recovered. The review decision flags any pin that has neither a source page nor a quote, and each pin keeps its confidence score where it has one.
04
Functions keep their source.
Alternate functions come from the datasheet’s own table. A regression test fails if the STM32H743’s PE2 loses its ETH, FMC or SPI groups, or gains a UART tag it does not have.
05
A printed land pattern comes first.
For KiCad footprints, a land pattern the datasheet prints is used as printed. Where it prints none, land dimensions are calculated from the package’s lead dimensions with simplified IPC-7351B formulas.
06
CAD files are loaded by KiCad’s own tool.
Where KiCad’s command-line tool is available, the generated symbol and footprint files are loaded with it, and the CAD pack records whether they passed. If it did not run, the pack says so.
On a real run
The AM6442 run, in its own files.
Our pinout run of 11 July 2026 on TI’s AM6442 datasheet recovered 441 of 441 balls. The verifier passed, and the decision left the 196 balls with several functions for a person to review. These are excerpts of the files it stored. The full run is in the run report.
{
"status": "approved_with_warnings",
"human_review_required": true,
"reasons": [
"196 pin(s) have multiple functions and require mux review."
],
"blocked_outputs": [],
"next_action": "Use this pinout as review-level truth. Verify warnings before downstream automation.",
"machine_use": {
"safe_for_ai_reasoning": true,
"safe_for_cad_symbol_seed": true,
"safe_for_pin_capability_graph": true,
"safe_for_package_crosscheck": true
}
}{
"status": "passed",
"signals": {
"expected_pin_count": 441,
"actual_pin_count": 441,
"coverage_ratio": 1,
"pins_with_source_page": 441,
"pins_with_source_snippet": 441,
"pins_with_confidence_score": 441,
"pins_with_functions": 296,
"unknown_type_count": 0
},
"failed_expectations": []
}What the checks miss
A clean verdict is not a correct answer.
The same run passed every check and still got something wrong.
Every check passed.
441 of 441 balls, each with a page, a quote and a confidence score, and no failed expectations.
203 balls had the wrong name.
They were named PADCONFIG, a word from the register column of TI’s table, instead of their own names. No check asks whether 203 signal balls sharing one name is plausible.
Because every row kept the line it was read from, the cause could be traced to the table. Read how it happened, and the planned fix.
What stays with you
What you should still check.
The package.
Make sure the run used the package on your board. The output records which one it used.
A few rows against the page.
Especially where a table wraps a cell onto several lines, or where one name repeats.
The review decision.
It says what the result is safe for, and what it left for a person, such as pins with several functions.
Everything, before production.
Every output is review-level: a first draft that shows its sources, not a signed-off library part.
Questions
Common questions.
Does DatasheetVend guarantee that an extraction is correct?
No. Every output is review-level. A run keeps its evidence, its warnings and a review decision so that a person can check it, and nothing is marked production-approved.
What does safe_for_cad_symbol_seed mean?
That the pinout passed its verifier, every pin has source evidence (a page or a quote) and no numbering check contradicted it, so it can start a CAD symbol. The symbol still needs an engineer’s review before production.
What happens when a run finds a problem?
It stays in the output, as a warning, as a reason in the review decision, or as an output the decision blocks. A blocked pinout’s decision says not to use it for CAD seeds or machine reasoning until the problem is resolved.
Run one on a datasheet you have.
A new account gets five free passes. Each pass runs up to two modules, pinout and footprint included, on a PDF up to 25 MB.